Installation and Replacement of Power and Weatherproof Outlets.
Modern electrical safety standards in Thailand require the replacement of outdated Type A/B outlets (without grounding) with Type B/F outlets (with grounding pin). Our certified engineers perform urgent installation, modernization, and relocation of electrical points, considering the specifics of the tropical climate and the strict requirements of the Thai Industrial Standards (TIS) 2026.
Critical Requirements of the 2026 Standard for Phuket:
-
Outlet Type: Mandatory use of Type B (15A, 125V) and Type F (Schuko, 16A, 250V) outlets with grounding. Prohibition on installing outdated Type A.
-
Materials: Heat-resistant back boxes made of self-extinguishing plastic (UL94 V-0), weatherproof gaskets.
-
Protection: RCBO/ELCB circuit breakers (Residual Current Circuit Breaker with Overcurrent protection / Earth Leakage Circuit Breaker) on each circuit in the distribution board.
-
Wiring: Copper cables THW, VAF, NYY with a cross-section of at least 2.5 mm² for socket circuits.
Specialized Solutions for Phuket Real Estate:
For Private Villas and Townhouses (Surin, Kamala, Bang Tao):
-
Installation of weatherproof outlets IP66/IP67 for open-air kitchens, outdoor BBQ areas, pool decks.
-
Installation of power outlets for electric stoves and ovens (20-32A) with a dedicated circuit from the distribution board.
-
Integration of Smart Wi-Fi Outlets with remote control for irrigation, lighting, and security systems.
For Condominiums and Apartments (Patong, Kata, Karon):
-
Safe replacement of old outlets without damaging finishes (porcelain tile, decorative plaster).
-
Installation of outlets with USB Type-C ports (PD 65W+) for gadget charging.
-
Organization of functional outlet blocks of 3-5 units in kitchens and media areas.
For Commercial Real Estate (Hotels, Restaurants, Cafes):
-
Installation of vandal-resistant outlets (IK08 rating) in public lobby and corridor areas.
-
Installation of specialized outlets for professional equipment: coffee machines, grills, refrigeration showcases.
-
Organization of power supply for yacht piers and marinas: outlets for shore power connection.
Installation Process:
-
Audit and Testing: Checking voltage, presence of grounding, condition of old wiring using a multimeter and tester.
-
Demolition: Careful removal of the old outlet, assessment of wire and back box condition.
-
Preparation: Replacement of the back box if necessary, stripping and preparing wires.
-
Connection: Connecting the live (L), neutral (N), and protective earth (PE) wires to the corresponding terminals. Using WAGO lever-nuts or crimping with sleeves.
-
Installation: Securing the mechanism in the back box, mounting the faceplate.
-
Testing: Checking voltage, operation of RCCBs/ELCBs, polarity, and grounding using a professional tester.
Dangers of Low-Quality Outlets in Phuket Conditions:
-
Contact corrosion due to salty air leads to overheating and fire.
-
Lack of grounding risks electric shock when using appliances near pools and in wet areas.
-
Mismatched load capacity leads to plastic melting when connecting powerful air conditioners and kitchen appliances.
Our engineers hold Provincial Electricity Authority (PEA) licenses and manufacturer certifications (Legrand, Schneider Electric, ABB). We use only certified materials compliant with TISI standards.